Cups and spatulas, micro engraver, charge element for resin, mould removal agent, cold mounting moulds, blade holder and holding clips...
Fluorescent contrast dye to be mixed with clear mounting resins, highlights porosity and micro-cracks. Requires the use of filters on the microscope for optimal results. The wavelength at maximum absorbance is 438-440 nm. Mainly used with LAM PLAN 603 and 603.2 epoxy resins.
Characteristics |
Qty | Ref. |
EPOCHROME powder | 20 g pot | 06 0EPCH 00 |
Ø |
Ref. | ||
Ø 25,4 mm or 1” for double mounting | 60 PL2I1 10 | ||
Ø 30 mm for double mounting | 60 PL2I2 00 | ||
Ø 40 mm for double mounting | 60 PL2I4 00 | ||
Ø 50 mm for double mounting | 60 PL2I5 00 | ||
Ø 1”1/4 for double mounting | 60 PL2I2 10 | ||
Ø 1”1/2for double mounting | 60 PL2I4 10 | ||
Ø 2” for double mounting | 60 PL2I5 10 |
Ø |
Ref. | ||
Ø 25,4 mm ou 1” | 60 PL1C1 00 | ||
Ø 30 mm | 60 PL1C2 00 | ||
Ø 40 mm | 60 PL1C4 00 | ||
Ø 50 mm | 60 PL1C5 00 | ||
Ø 1”¼ | 60 PL1C2 10 | ||
Ø 1”½ | 60 PL1C4 10 | ||
Ø 2” | 60 PL1C5 10 |
Ø |
Ref. | ||
Ø 25.4 (1”), 30, 40, 1’’¼ et 1’’½ | 60 PL2H1 00 | ||
Ø 50 et 2’’ | 60 PL2H2 00 |
For the vertical positioning of thin sections, to use of could mounting resin.
Type |
Qty | Thickness (mm) | Ref. |
Blade-holder series 690 | 100 | 1 | 06 00690 10 |
Blade-holder series 691 | 100 | 2 | 06 00690 20 |
Blade-holder series 692 | 100 | 3 | 06 00690 30 |
Types |
Characteristics | Qty | Ref. |
Plastic clips to use with cold mounting resin | Plastic, raised | 100 | 06 00694 00 |
Types |
Characteristics | Qty | Ref. |
Metal clips to use with hot mounting resin | Metal | 100 | 06 00693 00 |
Mainly used with the transparent mounting resins (601.2, 609, 603).
Type |
Qty | Dim. (mm) | Ref. |
681 | 5 | 25 | 06 00681 10 |
5 | 30 | 06 00681 20 | |
5 | 32 | 06 00681 30 | |
5 | 40 | 06 00681 40 |
Specifically, for cold mounting resin, adapted to complex and nonstandard shapes, many
dimensions available, made of a flexible material to facilitate mould removal, (For an intensive use of Epoxy 603, it is preferable to use removable bottom moulds).
/ Any other dimensions on request.
Type |
Qty | Dim. (mm) | Ref. |
Flexible 670 | 5 | 70 x 30 x 40 | 06 00670 10 |
5 | 100 x 42 x 30 | 06 00670 20 | |
5 | 120 x 50 x 30 | 06 00670 30 | |
5 | 100 x 70 x 30 | 06 00670 40 | |
Flexible 670 4 pieces set |
1 | 70 x 30 x 40 | 06 00670 00 |
1 | 100 x 42 x 30 | ||
1 | 120 x 50 x 30 | ||
1 | 100 x 70 x 30 |
Available in all standard diameters for central and individual pressure sample holders, made of a flexible material to facilitate mould removal. (For an intensive use of the EPOXY 603 resin, it is preferable to use moulds with removable bottoms).
Type |
Qty | Dim. (mm) | Ref. |
Flexible 625 | 5 | Ø 25 | 06 00625 00 |
Flexible 630 | 5 | Ø 30 | 06 00630 00 |
Flexible 632 | 5 | Ø 32 | 06 00632 00 |
Flexible 640 | 5 | Ø 40 | 06 00640 00 |
Flexible 650 | 5 | Ø 50 | 06 00650 00 |
Flexible 660 | 5 | Ø 60 | 06 00660 00 |
The LAM PLAN universal sample-holder mould is a smart and economical system which combines the functions of both mounting mould and sample-holder for cold mounting
processes using any kind of liquid resin. This system has been developed as two removable parts: the metallic universal sample-holder with non-stick coating and a special silicon based flexible mould to embed your cold mounting samples.
The 610 sample holder can be used on both automatic and semi-automatic machines. It
is directly compatible with the SMARTLAM®2.0 fitted with the SPRINGLAM® pressure arm. An adaptor kit is available for use with an automatic machine with motorised head.
Designations |
SMARTLAM® 2.0 option SPRINGLAM® |
MASTERLAM® 1.0 MASTERLAM®3.0 |
Ref. |
Ø 110 mm with 6 x Ø 28 mm cells | Ø 200 mm | 06 00612 20 | |
Ø 145 mm 3 moulds 6 included cells 6 x Ø 40, 6 x Ø 35 and 6 x Ø 32 mm |
Ø 250 - 300 mm |
Ø 250 - 300 mm |
06 00614 10 |
Ø 145 mm with 3 moulds 6 included cells 6 x Ø 30, 6 x Ø 25 and 6 x Ø 20 mm |
Ø 250 - 300 mm |
Ø 250 - 300 mm |
06 00614 20 |
Ø 145 mm with moulds 3 x Ø 50 mm cells | Ø 250 - 300 mm |
Ø 250 - 300 mm |
06 00614 30 |
Ø 145 mm with 2 moulds 3 included rectangular cells 3 x 30 x 55 mm and 3 x 18 x 55 mm | Ø 250 - 300 mm |
Ø 250 - 300 mm |
06 00614 40 |
Ø 159 mm with mould 6 x Ø 36 mm cells | Ø 250 - 300 mm |
Ø 250 - 300 mm |
06 00612 40 |
Ø 159 mm with mould 10 x Ø 28 mm cells | Ø 300 mm | Ø 300 mm | 06 00612 50 |
Universal sample holder ADAPTOR KIT for MASTERLAM®1.0 and 3.0 |
X | 06 K0010 00 |
In order to use the universal sample-holders with the SMARTLAM®2.0, the machine must be fitted with a SPRINGLAM® pressure arm. The universal sample-holders are not compatible with the individual pressure.®.
Paper cups and wooden spatulas to mix cold mounting resins.
Characteristics |
Qty | Capacity (ml) | Ref. |
Paper cups | 200 | 200 | 06 00696 00 |
SET: paper cups & spatulas |
400 cups |
06 00698 00 |
To mark and identify samples.
Characteristics |
Ref. | ||
Speed 0-20 000 rpm |
10 88630 00 |
The Voluma spheres are ceramic balls used as sole or base. They allow increasing the hardness of the mounting resins and decrease their shrinkage in order to reduce fallen edge effects. They are adapted to all types of hot and cold mounting resins; available in various colours to personalize samples.
Characteristics |
Qty (cm3) | Ref. | |
Ivory | 250 | 06 007SV 30 |
Recommended for PHENOFREE, 633 and 634 resins.
Characteristics |
Qty | Ref. | |
Anti-stick powder for hot mounting process | 50 g pot | 06 00683 00 |
The health situation makes it necessary to adapt our organization and the activity of our services.
Committed to providing you with quality answers, we invite you to send us a message with your contact details so that our staff can answer you as soon as possible.